ELECTRICAL CONTACTS

DDC Series

The main function is to transmit the flow of electric current only when the door is closed.

The DDC1 models include two nickel-plated brass terminal blocks and the DDC2 models have been silver-plated for better conductivity.

The electrical contacts have been redesigned on the inside to offer easy installation of the wiring and thus be able to transmit the electrical current correctly.

DDC Series Instructions

Constant current flow

For situations where the electromechanical lock requires a constant electrical pulse for activation.
The minimum current intensity is 0.5 A.

Compatible with lock operation Fail-secure (negative security) and reverse (positive security).

Intermittent current flow

For those situations where the electromechanical lock only requires a single electrical pulse for activation.
The minimum current intensity is 1.5 A.

Compatible with the operation of the lock Fail-secure (negative security).

DDC Series

Most relevant characteristics

Silver plated terminals

The constant current electrical contacts incorporate silver-plated brass terminals, ensuring optimum electrical conductivity.

Reliable contact

Constant current electrical contacts feature two identical contacts, reducing oxidation and simplifying wiring installation.
This ensures efficient transmission of electrical current even in mismatched doors.

Available models

DDC1K

Two connection terminals

Flujo de corriente intermitente
24V AC/DC <1min
79 mm x 13 mm x 10 mm

DDC1W

Two connection terminals

Flujo de corriente intermitente
24V AC/DC <1min
79 mm x 13 mm x 10 mm

DDC2K

Two connection terminals

Constant current flow
24V AC/DC ED100%.
86 mm x 20 mm x 22.2 mm

DDC2W

Two connection terminals

Constant current flow
24V AC/DC ED100%.
86 mm x 20 mm x 22.2 mm

DDC3K

Three connection terminals

Constant current flow
24V AC/DC ED100%.
86 mm x 20 mm x 22.2 mm

DDC3W

Three connection terminals

Constant current flow
24V AC/DC ED100%.
86 mm x 20 mm x 22.2 mm

DDC4K

Four connection terminals

Constant current flow
24V AC/DC ED100%.
86 mm x 20 mm x 22.3 mm

DDC4W

Four connection terminals

Constant current flow
24V AC/DC ED100%.
86mm x 20mm x 22,3mm